Resistance Inspection
Note
1. Disconnect MAF/IAT sensor.
2. Measure the resistance between the MAF/IAT sensor terminals D and E using an ohmmeter.
Specification
Circuit Open/Short Inspection
1. Disconnect the PCM connector. (See PCM REMOVAL/INSTALLATION.)
2. Inspect the following wiring harnesses for open or short. (Continuity check)
Open circuit
- MAF/IAT sensor terminal D (harness-side) and PCM terminal 2E (harness-side)
- MAF/IAT sensor terminal E (harness-side) and PCM terminal 2H (harness-side)
Short circuit
- MAF/IAT sensor terminal E (harness-side) and power supply
- MAF/IAT sensor terminal D (harness-side) and power supply
- MAF/IAT sensor terminal D (harness-side) and body GND
Mazda 6 Service Manual: Automatic Transaxle Controls
Various Lockouts:
Indicates that you must depress the brake
pedal and hold in the lock-release button to shift (The ignition must be switched
ON).
Indicates the shift lever can be shifted
freely into any position.
Indicates that you must hold in the lock-release
button to shift.
N ...
Mazda 6 Service Manual: No.9 tcs off light stays on more than 4 seconds with ignition switch on
When performing an asterisked (*) troubleshooting inspection, shake the
wiring harness and connectors while
doing the inspection to discover whether poor contact points are the cause
of any intermittent malfunction. If
there is a problem, check to make sure connectors, terminals and ...