Warning
Caution
1. Place a battery in a pan of water to prevent it from overheating.
2. The water level should come up about halfway on the battery.
3. Remove the battery plugs while charging the battery.
4. Keep water off the top of the battery.
Caution
5. Connect a battery charger to the battery.
6. Adjust the charging current as follows.


Battery inspection
Generator removal/installationMazda 6 Service Manual: Battery Maintenance
To get the best service from a battery:
Keep it securely mounted.
Keep the top clean and dry.
Keep terminals and connections clean, tight, and coated with petroleum jelly
or terminal grease.
Rinse off spilled electrolyte immediately with a solution of water and baking
soda.
If th ...
Mazda 6 Service Manual: Oil control valve (ocv) inspection
L3
Coil Resistance Inspection
1. Disconnect the negative battery cable.
2. Disconnect the oil control valve connector.
3. Measure the resistance between terminals A and B using an ohmmeter.
If not as specified, replace the oil control valve.
Specification
6.9-7.9 ohms
4. Connect ...