1. Install the SST
(gas charging set).
2. Disconnect the refrigerant pressure switch connector.
3. Verify the high-pressure side reading of the SST
(manifold gauge) and continuity between the terminals of the refrigerant pressure switch.
Triple-pressure Type



Dual-pressure Type


Refrigerant pressure switch removal/installation
Climate control unit removalMazda 6 Service Manual: Actuator cable installation
1. Slide the lock lever in the direction shown by the arrow to unlock the
adjuster.
2. Turn the ratchet ring to release lock in the direction shown by the arrow.
3. Install the actuator cable to the cruise actuator.
Caution
Due to the possibility of actuator cable damage, make sure th ...
Mazda 6 Service Manual: Intake-air system removal/installation
Warning
When the engine and intake-air system are hot, they can badly
burn. Turn off the engine and wait until they are cool before removing the
intake-air system.
Fuel vapor is hazardous. It can easily ignite, causing serious