1. Install the SST
(gas charging set).
2. Disconnect the refrigerant pressure switch connector.
3. Verify the high-pressure side reading of the SST
(manifold gauge) and continuity between the terminals of the refrigerant pressure switch.
Triple-pressure Type



Dual-pressure Type


Refrigerant pressure switch removal/installation
Climate control unit removalMazda 6 Service Manual: Side protector installation
1. Remove the adhesive remaining on the side protector (if it will be reused)
and the body using a razor.
2. Remove any grease or dirt from the adhesion surface of the side protector
(if it will be reused) and the body.
3. Attach double-sided adhesive tape to the side protector as shown (if it ...
Mazda 6 Service Manual: Electrical parts
Battery cable
Before disconnecting connectors or removing electrical parts, disconnect
the negative battery cable.
Wiring Harness
To remove the wiring harness from the clip in the
engine room, pry up the hook of the clip using a
flathead screwdriver.
...